Our safeguards

  • Our web interface uses supports 256 bit TLS encryption.

  • iOS apps use Our iOS, Android, Webview, and PC clients support 256 bit TLS encryption for data transfersDatabase-to-database transfers (for the CDN server network) are encrypted.

  • Data stored in our databases is encrypted at rest and when in transit.

  • All passwords are SHA Argon2 hashed.

  • All Active911 personnel with access to the data have passed criminal background checks.

...

Data Centers

We use multiple AWS data centers . Our primary data center is SAS-70 Type II / SSAE-16 Certified, located in the heart of downtown Dallas, TX. It is in a Tier 3+ facility on the same protected power grid as Dallas 911 and the local hospitals. Power is sent to the data center from four different substations, requiring all four substations to go offline before power to the building is interrupted. Additionally, the data center is serviced by water feeds from the north and south of the building.located in Oregon and Ohio. AWS' data centers have been validated by third-party testing performed against the NIST 800-53 Revision 4 controls, as well as additional FedRAMP requirements. AWS data center locations are carefully selected to mitigate environmental risks, such as flooding, extreme weather, and seismic activity. Each data center has 24/7/365 on site security

...

Card access required to gain access to parking and building lobby, biometric hand scanner required for data center entry

...

Annual SSAE 16 & PCI-DSS Audits

...

Multiple 360 degree cameras with 10x zoom, high speed recorders with DV cassette tapes, hard drives to eliminate down time for tape swaps and over recording

...

True A+B (2N) power configurations

...

2(N+2) Transformers and feeds

...

All UPS and Generator deployments provide (2N) redundancy

...

Entire cooling system is designed with at least N+1 redundancy

...

Multiple utility feeds from the CBD grid

...

Feeds to building are concrete encased

...

80,000 gallon reserve make-up water tank

We also utilize a smaller Oregon datacenter for geographic diversity and redundancy.

AWS data centers are designed to anticipate and tolerate failure while maintaining service levels. In case of failure, automated processes move traffic away from the affected area. We currently don’t, but are working towards core applications being deployed to an N+1 standard, so that in the event of a data center failure, there is sufficient capacity to enable traffic to be load-balanced to the remaining sites.

Physical access points to server rooms are recorded by Closed Circuit Television Camera (CCTV). Images are retained according to legal and compliance requirements.

AWS data center electrical power systems are designed to be fully redundant and maintainable without impact to operations, 24 hours a day. AWS data centers are equipped with back-up power supply to ensure power is available to maintain operations in the event of an electrical failure for critical and essential loads in the facility.

Details